2024 Ludlums - Network and Relay Options. 48-Hour Battery Backup. CE Certified. The Model 375 is a versatile, compact, and easy-to-use digital electronic controller designed for monitoring radiation in areas. Its simple design accommodates many different detectors to suit a wide variety of applications, and it is equipped with a local readout and alarms.

 
The Model 2241-4 is a portable neutron REM meter. This instrument combines Ludlum's microprocessor-based digital Scaler-Ratemeter Model 2241 electronics with a Model 42-31H Neutron Detector. This system is sensitive to neutrons from thermal to 12 MeV with a response approximating the inverse RPG curve for neutron dose.. Ludlums

Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment.The Ludlum Model 23-1 mSv Electronic Personal Dosimeter is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is required ...Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and material monitoring ...Includes Check Source and Holder. The 14C-RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the robust and versatile Model 14C Survey Meter, which houses an internal energy compensated GM ...Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ...Shipping Address. All instruments requiring service should be shipped to the following address: Ludlum Measurements, Inc. Attn: Service Department. 501 Oak Street. Sweetwater, TX 79556. USA.The Model 243, along with a pulse height analyzer system, is used for gamma ray assay and wipe test analysis. The Model 243 is shielded with 1.3 cm (0.5 in.) of lead to improve sensitivity by reducing background and other external radiation. The detector is an integrated 4.5 x 5.1 cm (1.8 x 2 in.) (Dia x thickness) NaI (Tl) crystal scintillator ...2 days ago · Serial Number Reading Units Cumulative Dose Cumulative Start Cumulative Reset Site Building Area Location Status Alarm Message Received IP Address; 237025: 3.00 Ludlum Measurements Inc, Sweetwater, Texas. 490 likes · 1 talking about this · 801 were here. Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection …Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment. Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool. The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence. Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672 Includes up to 12 gas proportional or scintillation detectors for surveying large areas mounted on a roll-around cart. Configurations: Model 240 Gas Proportional Floor and Wall Monitor. Model 240S Scintillation Floor and Wall Monitor. Model 240-1 Gas Proportional Floor Monitor. Model 240S-1 Scintillation Floor Monitor. 48-3956. Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool. The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS (Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. …Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website.Model 375 Webpage & Service Software. Collects and displays radiation levels and alarm status from up to 50 Model 375 instruments. The Model 375 must be equipped with Ethernet interface. Using this interface, the area monitor can be connected to the network allowing for real-time monitoring of radiation data, email alerts, and database logging.The Model 375-20 is a Digital Model 375 Controller coupled to two shielded 5.1 cm (2 in.) diameter by 5.1 cm (2 in.) thick NaI (Tl) scintillation detectors. The detectors are encased in weathertight enclosures suitable for the outdoor environment, but the Model 375 Controller is normally mounted to a wall indoors near an operator. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. Part Number: 2002-1050. Ludlum offers an energy compensation filter that flattens the energy response of our popular Model 44-9 GM pancake detector and Model 26-Series friskers to facilitate measuring Ambient Equivalent Dose (Sieverts). The venerable GM pancake has a significant over-response at lower energies between approximately 20 to …Robert Ludlum (born May 25, 1927, New York, N.Y., U.S.—died March 12, 2001, Naples, Fla.) U.S. author of spy thrillers.He worked in the theatre as an actor and a successful producer and acted for television before turning to writing. Among his best-sellers were The Scarlatti Inheritance (1971), The Osterman Weekend (1972; film, 1983), The …This general purpose, handheld analog ratemeter supports GM, proportional, and scintillation type detectors. The analog meter face comes in a variety of options to support the measurement units and ranges for the optional external detector selected. The cast aluminum instrument housing with its separate battery compartment and accompanying ...Robert Ludlum bibliography. Robert Ludlum (1927–2001) was an American author of twenty-seven novels between 1971 and 2006, the last being issued five years after his death. [1] Of his twenty-seven novels, two were originally published under the pseudonym of Jonathan Ryder and another under the pseudonym of Michael Shepherd. The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area. The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ... Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website. The Model 44-3 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 5 cm 2 (0.8 in 2 ) active window area. Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment. This gamma/neutron survey meter combines Ludlum Model 2363 survey meter with the Model 42-41L PRESCILA neutron detector. The gamma detector is an energy compensated GM housed internally to the survey meter. The neutron detector is a proton recoil type, which provides excellent measurement results at less weight than the more traditional REM balls. The Model 44-88 is a pancake GM detector for measuring alpha, beta, and gamma radiation. It has a 15 cm 2 (2.3 in 2 ) active window area.The Model 53 Gamma Personnel Portal detects gamma radiation in or on personnel passing through the portal from either direction. This highly sensitive portal uses eight large plastic scintillation detectors. Shielding is accomplished with either the standard 2.5 cm (1 in.) or optional 5.1 cm (2 in.) thickness of lead.The Model 3030 Alpha-Beta Sample Counter incorporates an internally housed ZnS (Ag) plastic scintillator detector with shielded 5.1 cm (2 in.) diameter stainless steel sample tray into the Ludlum Model 3030 Scaler. …4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, analog ratemeter known for accuracy and long-lasting dependability. It comes in a variety of measurement ranges and units to support the external radiation detector selected.Features. The Model 9DP-1 is a digital, hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. This meter is specially designed for radiography work where pulsed fields are being measured.Part Number: 2002-1050. Ludlum offers an energy compensation filter that flattens the energy response of our popular Model 44-9 GM pancake detector and Model 26-Series friskers to facilitate measuring Ambient Equivalent Dose (Sieverts). The venerable GM pancake has a significant over-response at lower energies between approximately 20 to …Ludlum Measurements Inc, Sweetwater, Texas. 490 likes · 1 talking about this · 801 were here. Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection instruments and techRobert Ludlum was the author of twenty-seven novels, each one a New York Times bestseller. There are more than 210 million of his books in print, and they have been translated into thirty-two languages. He is the author of The Scarlatti Inheritance, The Chancellor Manuscript, and the Jason Bourne series--The Bourne Identity, The Bourne ... Features. The Model 3019 is a portable and versatile instrument with an internal detector used for background measurements of gamma radiation levels up to 500 µSv/h (50 mR/hr). The internal CsI scintillation detector has a sensitivity of 175 cpm per µR/hr. It features a large, easy-to-read LCD screen and audible alarms and is controlled using ... The Model 44-20 is a NaI(Tl) scintillator detector for measuring gamma radiation. It has a 137 Cs sensitivity of 2300 cpm per μR/hr.The Model 43-92 is a ZnS(Ag) scintillator detector for measuring alpha radiation. It has a 100 cm 2 (15.5 in 2 ) active window area.The Model 375P-1000 is a digital Model 375 Controller coupled to two shielded 7866 cm 3 (480 in 3) plastic scintillator detectors. The detectors are encased in weathertight enclosures suitable for the outdoor environment. The Model 375 Controller is not weatherproof and must be mounted either indoors or within an environmental enclosure ... Features. The Model 3019 is a portable and versatile instrument with an internal detector used for background measurements of gamma radiation levels up to 500 µSv/h (50 mR/hr). The internal CsI scintillation detector has a sensitivity of 175 cpm per µR/hr. It features a large, easy-to-read LCD screen and audible alarms and is controlled using ... 2 days ago · Serial Number Reading Units Cumulative Dose Cumulative Start Cumulative Reset Site Building Area Location Status Alarm Message Received IP Address; 237025: 3.00 The Ludlum Model 23-1 mSv Electronic Personal Dosimeter is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is required ...4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, …The Ludlum Model 3000 is a durable, lightweight instrument that is used with an external detector for alpha, beta, and gamma radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic, and splash-resistant construction ...The Model 43-9 is a sample counter head with a ZnS(Ag) scintillator detector for measuring alpha radiation. It can hold samples up to 2.5 cm (1 in.) dia. Ludlum Measurements, Inc. Calibration Department Tennessee Division. 10744 Dutchtown Road. Knoxville, TN 37932. Phone (Toll Free): 888-707-1795. Phone: 865-392-4601. Email: The privacy policy for the Ludlum Measurements website. Features. The Model 9DP is a digital, hand-held pressurized ion chamber that provides highly sensitive exposure measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Measurements and instrument status are displayed on a large, 232K-color, backlit LCD screen.Part Number: 48-1677. The Ludlum Model 500 Pulse Generator provides the functions necessary for use in calibrating Ludlum radiation detection instruments as well as many other scaler/ratemeter instruments from other manufacturers. The adjustable output pulse rate is displayed on a three-digit LED readout. Potentiometers (both coarse and fine ... External GM or Scintillation Detector. This general purpose, handheld analog ratemeter supports operating two separate radiation detectors. A switch allows the user to select between the internally mounted GM detector with an exposure range of 0 - 20 mSv/h (0 - 2000 mR/hr) or an external GM or scintillator detector of choice (see table below). The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ... Metal Recycling Catalog. This catalog presents all instrumentation to detect, locate and identify threatening radioactive sources that might find their way into the scrap metal yards. To receive the print version, request PN: 03-6020. The privacy policy for the Ludlum Measurements website. The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence. Features. The Model 3005 is a durable, lightweight instrument with an internal energy-compensated GM detector for radiation survey. It features a large, easy-to-read LCD screen and audible alarms and is controlled using a simple five-button interface. The unit body is made of high-impact plastic and splash-resistant construction allows the ... Features. This intrinsically safe general purpose ratemeter is patterned after Ludlum's best-selling Model 3. It was designed and tested to USA standards for intrinsic safety, permitting it to be used in potentially explosive atmospheres. The Model 3-IS can only be used with select detectors to sustain the intrinsic safety rating.Metal Recycling Catalog. This catalog presents all instrumentation to detect, locate and identify threatening radioactive sources that might find their way into the scrap metal yards. To receive the print version, request PN: 03-6020. The privacy policy for the Ludlum Measurements website.When contacting us through email, please remember to fill in the "Subject" line so that we can quickly assess your needs. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Office Hours: 8:00 am - 5:00 pm CST, Monday - Friday. Toll Free: 800-622-0828 (US & Canada) Tel: 325-235-5494. Fax: 325-235-4672.The Ludlum Model 23 mrem Electronic Personal Dosimeter (EPD) is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is ...Temperature dependent. Drop Resistance. Survives 100g drops in three orientations. Size (H x W x L) 25.7 x 10.8 x 10.8 cm (10.125 x 4.25 x 4.25 in.) Weight. 2.2 kg (5 lb) Note: For gamma backgrounds greater than 100 mR/h, we recommend using Model 42-31H. Model.4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, analog ratemeter known for accuracy and long-lasting dependability. It comes in a variety of measurement ranges and units to support the external radiation detector selected.Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment. The Model 4600 Series are SCAs (single channel analyzers), ranging from 1 to 12 channels, with PC control of all necessary operating parameters. Each connected detector has independent high voltage, threshold or sensitivity, and window settings. Parameters are loaded from a built-in flash memory during the power-up sequence. Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Ludlum's Produce, Supply, North Carolina. 3,640 likes · 17 talking about this · 305 were here. Ludlum's Produce is a family owned and operated seasonal business with “ Fresh … This device may be mounted to the Model 177-Series of benchtop counters to provide protection against unintended modifications to the instrument's alarm setting. It is constructed of aluminum and has two drilled holes for screw-mounting it to the instrument. 7328-021. Description. Part Number. The Model 375/2 Digital Wall-Mount Area Monitor is designed for visibility and ease of use. This monitor incorporates an internally-housed energy compensated GM detector with a range from 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr). It features a wall-mount chassis and a four-digit LED display that is readable from 9 meters (30 feet) away.About Robert Ludlum’s The Bourne Shadow. When secrets from Bourne’s past come to light, he may be the next thing that’s buried in this latest entry in the legendary New York …About Robert Ludlum’s The Bourne Shadow. When secrets from Bourne’s past come to light, he may be the next thing that’s buried in this latest entry in the legendary New York Times bestselling series. It’s been over a decade since Nash Rollins recruited a brilliant, talented, but disaffected young man named David Webb to join Treadstone. The Ludlum Model 44-172 YSO (Yttrium Oxyorthosilicate) detector is used primarily for the detection of low-energy gamma radiation, from approximately 5 keV to 145 keV. It will also detect beta energy as low as 49 keV. The detector consists of a 2.5 cm (1 in.) diameter by 1 mm (0.04 in.) thick YSO scintillator. The window area is approximately 5 ... Height Above Floor Easily Adjusted. Rate, Max, and Count Modes. The Model 3002/FM Series Alpha-Beta Floor Monitors allow a user to quickly survey large areas for alpha-beta contamination. They combine the dependable Model 3002 Alpha-Beta Survey Meter with two alpha-beta scintillation detectors in configurations ideal for floor monitoring.Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672Ludlum Measurements offers both Alpha-Beta Gas Proportional and Gamma Scintillator Detectors for use in surveying pipes and tubing. All detectors listed here include an eye on one or both ends to attach a pull rope or cable. Click on the model number to view the product drawing or main product page. Product. Description. Part Number. Model 43-94.Mar 15, 2024 · The Treadstone Books (by Joshua Hood) View on Amazon. The Treadstone series is a new spin-off saga set in Robert Ludlum’s iconic Bourne universe. Jason Bourne was an unforgettable agent in the top-secret CIA Black Ops program, Operation Treadstone. Now, author Joshua Hood has created a new protégé, Adam Hayes. The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ... These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range.Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-46722 days ago · Serial Number Reading Units Cumulative Dose Cumulative Start Cumulative Reset Site Building Area Location Status Alarm Message Received IP Address; 237025: 3.00 Indoor/Outdoor Use. Model 375-30. Two 7.6 x 2.5 cm (3 x 1 in.) (Dia x L) NaI (Tl) Scintillator Detectors. Lead Shielding. Indoor/Outdoor Use. Model 375P-336 Series. Two 2753 cm 3 (168 in 3) Plastic Scintillator Detectors. Range: 0 to 9999 kcps. Indoor or Outdoor Use Depending on Model. The Model 44-17 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 17.8 cm 2 (2.8 in 2 ) active window area. Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum. The Model 43-2-2 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 9.7 cm 2 (1.5 in 2 ) active window area. The Ludlum Model 44-172 YSO (Yttrium Oxyorthosilicate) detector is used primarily for the detection of low-energy gamma radiation, from approximately 5 keV to 145 keV. It will also detect beta energy as low as 49 keV. The detector consists of a 2.5 cm (1 in.) diameter by 1 mm (0.04 in.) thick YSO scintillator. The window area is approximately 5 ... Los toltecos, Daughters of the revolution, Premier high school, Nyc department of homeless services, Pelican brewery, Kcbs radio san francisco, Village in, Walmart sahuarita, Eric benet, The billings gazette, Mopop seattle, Westport ma horseneck beach, Grandview family medicine, Hawthorne stereo

This device may be mounted to the Model 177-Series of benchtop counters to provide protection against unintended modifications to the instrument's alarm setting. It is constructed of aluminum and has two drilled holes for screw-mounting it to the instrument. 7328-021. Description. Part Number. . Asher auction

ludlumsreeds ferry sheds hudson nh

Contact Information. You may Call, Fax, E-mail, or Mail your order to the following: LUDLUM MEASUREMENTS, INC. P.O. Box 810. Sweetwater, Texas 79556. PHONE: 800-622-0828 (USA and Canada) or 325-235-5494. FAX: 325-235-4672. E-MAIL: The privacy policy for the Ludlum Measurements website.Display. 4-digit LCD display with 1.3 cm (0.5 in.) high digits, separate annunciators for display units, alert, alarm, low battery, detector overload, counting overflow, and scaler counting. Display Range. Auto ranging from: 0.0 μR/hr to 9999 R/hr. 0.000 μSv/h to 9999 Sv/h. 0 cpm to 999 kcpm. 0 cps to 100 kcps. Backlight.Indicated Use. Tritium surface survey / Windowless beta survey. Designed to be placed on a flat surface and then purged with P-10 gas for 20 seconds before counting. Detector Type. Gas flow proportional. Window. Windowless. Window Area. Active: 126 cm 2 (19.5 in 2)Ludlum Measurements, Inc - The parent company, operating since 1962. A designer and manufacturer of radiation detection instrumentation and equipment used to monitor the safety of personnel and the environment. Ludlum Measurements, Inc. 501 Oak Street. Sweetwater, Texas 79556. USA. Tel: (325) 235-5494. Toll Free: (800) 622-0828 (US and …Includes Check Source and Holder. The 14C-RK Emergency Kit packages all the basic radiation measurement tools needed to handle a radiological emergency into a convenient carrying case to facilitate a quick response when required. The kit includes the robust and versatile Model 14C Survey Meter, which houses an internal energy compensated GM ... The Model HBP-29 is a whole-body contamination monitor designed to measure personnel leaving controlled areas. Standard features include: 29 beta plastic detectors with semiconductor readout. Stainless steel housing for easy cleaning and durability. Ergonomic detector positioning. Hand-detector on the side. Integrated 17 in. touch-screen display. The Model 43-89 is a ZnS(Ag) and plastic scintillator detector for measuring alpha and beta radiation. It has a 125 cm 2 (19.4 in 2 ) active window area. The Model 375 is a digital controller for radiation measurement or detection, compatible with many different detectors and applications. It has a large LED display, alarms, networkability, battery backup, and various options such as remote indicators, printers, relays, and more. This gamma/neutron survey meter combines Ludlum Model 2363 survey meter with the Model 42-41L PRESCILA neutron detector. The gamma detector is an energy compensated GM housed internally to the survey meter. The neutron detector is a proton recoil type, which provides excellent measurement results at less weight than the more traditional REM balls. The Ludlum Model 26S incorporates electronics and a miniature scintillation detector in an ergonomically designed, ruggedly-constructed, and water-resistant housing. The integrated unit doesn’t have a detector cable, thereby simplifying the process of frisking. The optimized configuration includes a standard 1 x 1 equivalent detector, loud ...Model 375 Webpage & Service Software. Collects and displays radiation levels and alarm status from up to 50 Model 375 instruments. The Model 375 must be equipped with Ethernet interface. Using this interface, the area monitor can be connected to the network allowing for real-time monitoring of radiation data, email alerts, and database logging.Model 375 Webpage & Service Software. Collects and displays radiation levels and alarm status from up to 50 Model 375 instruments. The Model 375 must be equipped with Ethernet interface. Using this interface, the area monitor can be connected to the network allowing for real-time monitoring of radiation data, email alerts, and database logging. The Model 44-3 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 5 cm 2 (0.8 in 2 ) active window area. The Model 52-1, 52-5, and 52-6 Series Portable Portal Monitors are used for beta-gamma contamination monitoring on personnel and meet the FEMA standard for Emergency Response Portal Monitoring (FEMA-REP-21). They are designed to be disassembled for ease of transportation and storage, and can be set up in five minutes or less without any … These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. The Ludlum Model 26S incorporates electronics and a miniature scintillation detector in an ergonomically designed, ruggedly-constructed, and water-resistant housing. The integrated unit doesn’t have a detector cable, thereby simplifying the process of frisking. The optimized configuration includes a standard 1 x 1 equivalent detector, loud ...Model 375 Webpage & Service Software. Collects and displays radiation levels and alarm status from up to 50 Model 375 instruments. The Model 375 must be equipped with Ethernet interface. Using this interface, the area monitor can be connected to the network allowing for real-time monitoring of radiation data, email alerts, and database logging. The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ... Meter Light. The Model 19 is a highly sensitive gamma microR meter employing an internally housed, 2.5 x 2.5 cm (1.0 x 1.0 in.) NaI detector. The measuring range is 0 to 5000 µR/hr. (For µSv/h, use Model 19 Series 8, P/N: 48-2582.) The cast aluminum instrument housing with a separate battery compartment and accompanying metal handle offer an ...Ludlum Measurements, Inc. (LMI) designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum, we offer a large array of …The Model 12-4 is an industry standard neutron dose rate instrument that conforms to the RPG curve with a measuring range of 0 to 100 mSv/h (0 to 10,000 mrem/hr) from thermal to 12 MeV. The detector is a 22.9 cm (9 in.) moderated 3 He tube with a gamma background rejection up to 100 mSv/h (10 R/hr). The ratemeter is a four-decade analog meter ...The Model 3-IS NORM Kit is composed of two dependable, high-quality detectors matched with the versatile Model 3-IS intrisically safe survey meter and packaged in a rugged transport and storage case. Users can connect either the Model 44-9 alpha-beta-gamma detector for general survey measurements or the Model 44-2 high-sensitivity gamma ...Robert Ludlum (born May 25, 1927, New York, N.Y., U.S.—died March 12, 2001, Naples, Fla.) U.S. author of spy thrillers.He worked in the theatre as an actor and a successful producer and acted for television before turning to writing. Among his best-sellers were The Scarlatti Inheritance (1971), The Osterman Weekend (1972; film, 1983), The … Features. Integrated, Lightweight Ergonomic Design. High-Impact Plastic with Water-Resistant Rubber Seals. Employs Standard 15.51 cm 2 GM Pancake Detector. Displays in mR/hr, µSv/h, dpm, Bq, cpm, or cps. Dead-Time Correction (DTC) Allows Gamma Measurements Up to 500 mR/hr or Up to 1999 µSv/h. Simple Three-Button Operation. The Model 375/2 Digital Wall-Mount Area Monitor is designed for visibility and ease of use. This monitor incorporates an internally-housed energy compensated GM detector with a range from 1 µSv/h to 10 mSv/h (0.1 mR/hr to 1 R/hr). It features a wall-mount chassis and a four-digit LED display that is readable from 9 meters (30 feet) away.Product Manuals. This section presents current product manuals for most of our instruments. They can also be found on the respective product pages under the Documents tab. Please check the serial number on your instrument to ensure it falls within the range of the serial numbers listed on the manual on this website.The world’s most ruthlessly efficient assassin, Jason Bourne, is facing the one force he can’t defeat—his own past—in the latest thrilling entry in Robert Ludlum’s New York Times bestselling series. Three years ago, Jason Bourne embarked on a mission in Estonia with his partner and lover, a fiery Treadstone agent code-named Nova. Their job was to …The Model 9DP-1* is a digital, hand-held pressurized ion chamber that provides highly sensitive ambient dose equivalent measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Ambient dose equivalent is defined as the dose equivalent readout that would be measured at a (human) tissue …Ludlum Measurements, Inc. 501 Oak Street Sweetwater, TX 79556 USA (800) 622-0828 (US & Canada) (325) 235-5494 (325) 235-4672Contact Information. You may Call, Fax, E-mail, or Mail your order to the following: LUDLUM MEASUREMENTS, INC. P.O. Box 810. Sweetwater, Texas 79556. PHONE: 800-622-0828 (USA and Canada) or 325-235-5494. FAX: 325-235-4672. E-MAIL: The privacy policy for the Ludlum Measurements website.The Model 44-40 Series are shielded GM (Geiger-Mueller) detectors capable of detecting alpha, beta, or gamma radiation. Both the Model 44-40 and 44-40-2 have lead shielding. The Model 44-40 has a painted lead … Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962, we offer a large array of radiation detection instrumentation, developed to help monitor the safety of personnel and the environment. Our instruments are used in applications such as routine personnel and material monitoring ... Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool. To reduce costs without compromising performance, the 375P-3500 system also utilizes Ludlum's highly popular Model 375 type controller that controls the detector, updates background, and carefully monitors the passing scrap metal. The controller can operate totally independently, or be wired for remote annunciation, or connected to an Ethernet ...Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech SupportIndoor/Outdoor Use. Model 375-30. Two 7.6 x 2.5 cm (3 x 1 in.) (Dia x L) NaI (Tl) Scintillator Detectors. Lead Shielding. Indoor/Outdoor Use. Model 375P-336 Series. Two 2753 cm 3 (168 in 3) Plastic Scintillator Detectors. Range: 0 to 9999 kcps. Indoor or Outdoor Use Depending on Model.The Model 375-20 is a Digital Model 375 Controller coupled to two shielded 5.1 cm (2 in.) diameter by 5.1 cm (2 in.) thick NaI (Tl) scintillation detectors. The detectors are encased in weathertight enclosures suitable for the outdoor environment, but the Model 375 Controller is normally mounted to a wall indoors near an operator.Emails sent by Ludlum Measurements will only use the "@ludlums.com" domain. If you are unsure about an email you may have received related to Ludlum Measurements, please contact us using the information here. (800) 622-0828 (US, CA) (325) 235-5494 (325) 235-4672. After Hours Tech SupportWe have over 160,000 sq. ft. (14,800 m 2) of manufacturing and office space. LMI's machining capabilities have significantly evolved over the years to support increasing production and efficiency requirements. We have a variety of manual and CNC machines that allow us to manufacture the large variety of parts we use in building our products.The Model 9DP-1* is a digital, hand-held pressurized ion chamber that provides highly sensitive ambient dose equivalent measurements of gamma and x-ray radiation at energies above 25 keV and beta radiation at energies above 1 MeV. Ambient dose equivalent is defined as the dose equivalent readout that would be measured at a (human) tissue …Ludlum Measurements, Inc. designs and manufactures radiation detection instruments and technologies. Founded in 1962 by Don Ludlum.Ludlum Measurements, Inc. is a designer and manufacturer of radiation detection equipment developed to help monitor the safety of personnel and the environment. The cable-less Model 26-2 consolidates the electronics and the detector into one ergonomic housing. This optimized configuration incorporates a standard GM pancake detector and large auto-ranging LCD display into one convenient package, making it easier than ever to detect contamination. Operation is simplified through the use of just two buttons. Each detector consists of a 2 atm 3 He detector (1.6 cm diameter x 2.5 cm thick), surrounded by a high density polyethylene sphere, 19.6 cm (7.7 inches) in diameter. This outer sphere moderates the incoming neutrons … Features. Integrated, Lightweight Ergonomic Design. High-Impact Plastic with Water-Resistant Rubber Seals. Employs Standard 15.51 cm 2 GM Pancake Detector. Displays in mR/hr, µSv/h, dpm, Bq, cpm, or cps. Dead-Time Correction (DTC) Allows Gamma Measurements Up to 500 mR/hr or Up to 1999 µSv/h. Simple Three-Button Operation. Features. Scaler / Ratemeter / Data Logger. Simultaneous Alpha & Beta Measurements with Audio Discrimination. Logs 550 Data Points. Analog & Digital Display. Six Separate Alarms. Overload Protection. RS-232 Port. If you need to separately count alpha and beta concurrently and log the results, the Model 2360 will be the right tool. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. These easy-to-use instruments incorporate a GM detector capable of measuring radiation fields up to 9.99 Sv/h (999 R/hr). The Model 25-IS Series backlit LCD readout displays dose rate, accumulated dose, and time remaining to the dose limit. Visual and audible alarms can be set over the entire measurement range. The Model 2224-1 is an optimized Alpha-Beta Scaler-Ratemeter that offers traditional analog readout, supplemented with a digital LCD for the scaler function. Simultaneous, separate counting of alpha and beta is featured on this instrument. A front-panel mounted, three-way switch facilitates selecting alpha only, beta only, or alpha plus beta.The Ludlum Model 23-1 mSv Electronic Personal Dosimeter is a compact and lightweight (60 g / 2 oz) pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is required ... 4-Range Analog Ratemeter. Supports GM & Scintillation Type Detectors. Greater than 2000 Hour Battery Life. The Model 3 is Ludlum's best selling, general purpose, handheld, analog ratemeter known for accuracy and long-lasting dependability. It comes in a variety of measurement ranges and units to support the external radiation detector selected. The Model 44-17 is a NaI(Tl) scintillator detector for 125 I and low-energy gamma radiation. It has a 17.8 cm 2 (2.8 in 2 ) active window area. The Model 3000 Series Bluetooth LE ® Option provides an encrypted wireless data connection between the instrument and an Android or iOS mobile device. Using the Lumic Linker app, this option allows the user to perform the following actions from their connected device: Remotely monitor live data. Remotely operate instrument buttons. The Ludlum Model 2200 Scaler/Ratemeter is the ideal economic solution for routine sample counting, single channel analyzing and routine radiopharmaceutical related procedures, when used with the Model 243 well scintillator (Nal) detector. The well counter's 4π geometry and 1.3 cm (0.5 in.) shielding provides excellent sensitivity to higher ... Alternative to Ludlum Models 18 and 2221. The Model 3003 is a durable, lightweight instrument designed for alpha, beta, gamma, or neutron radiation survey. It can support …The Model 43-92 is a ZnS(Ag) scintillator detector for measuring alpha radiation. It has a 100 cm 2 (15.5 in 2 ) active window area.. Kearney mo, National breast cancer coalition, River bank zoo columbia, Fgcu housing, Moores creek national battlefield, Fall river grill, Texas sunrise, Joanns fabric store website, South texas botanical gardens and nature center, Uh geauga, Sea odysea, Tybee island marine science center, T nail spa, Newbella shoes, Huey and weprin, Archiveorg, Used sporting equipment, Del mccoury.